Scope of application
NH00 With indicator fuse link This series of fuses is suitable for AC 50Hz, rated AC 500V, AC 690V,NH00 With indicator fuse link rated current is 100A. It is mainly used for electrical installation to protect circuits from overload and short circuit (gG/GL); It may also be used to protect semiconductor devices and other complete equipment from short circuits, as well as motor circuits from short circuits. The rated breaking capacity of this series of fuses is 120KA. This series of fuses complies with the International Electrical Commission standard IEC60269.
|
Model |
Rated Voltage (V) |
Rated current(A) |
Rated Breaking Capacity[kA) |
Rated dissipationpowerof fuse-link[w) |
|||
|
Base |
Fuse-Link |
AC500V |
AC690V |
DC250V |
|||
|
RT16-00 NH00 |
|
160 |
2,4,6,8,10,12,16, 20,25,32,40,50,63, 80,100 |
120 |
50 |
100 |
≤12W |
Notes:
atmospheric conditions
operational condition
The air is clean, and its relative humidity does not exceed 50% at a maximum temperature of 40 ℃.
At lower temperatures, there can be higher relative humidity, for example, at 20 ℃, the relative humidity can reach 90%.
Under these conditions, moderate condensation may occur accidentally due to temperature changes.
Under working conditions without obvious condensation, the relative humidity can reach 95%.
Installation, use, and maintenance of fuses.
Fuses should be installed indoors or in cabinets that are not affected by rain or snow, and should not be exposed and installed in easily accessible areas. When installing the fuse, it should be ensured that the electrical clearance is greater than 10mm and the creepage distance is greater than 20mm.
After the fuse is blown, it must be replaced with a new one of the same model, size, installation method, and rated current as the original fuse used
Do not replace fuses with copper wires or copper bars.
The replacement of fuses should be carried out by professionals, and this fuse should be used when cutting off the power supply. After replacing the fuse, it should be ensured that the fuse contacts well, Install firmly.
When cutting off the power and replacing the fuse link, please pay attention to removing dust and other dirt from the components connected to the fuse, so that the fuse is in good working condition.
During operation, the indicator of the fuse should be checked regularly to detect single-phase or phase loss operation in a timely manner.